Error code on your Bulex boiler?
Bulex boilers are renowned for their reliability and high performance.

However, like all technical equipment, they can sometimes break down.
The error codes that appear on your Bulex boiler’s display are vital indicators, signalling a variety of potential problems such as faulty sensors, overheating, water circulation problems or burner failure.
Neglecting these error codes can not only compromise the efficiency of your heating system, but also pose safety risks.
Boiler repair Bulex
At Leader Services, we know that having a reliable heating system is essential all year round, not just in winter. Our expert heating engineers are specially trained to handle all Bulex boiler error codes.
Thanks to our extensive experience and in-depth knowledge of these systems, we are able to quickly identify the causes of malfunctions and implement lasting solutions, guaranteeing optimum performance from your boiler in every season.
Our services include
– Precise diagnostics: Use advanced diagnostic tools to determine the exact cause of the error.
– Repair and replacement of faulty components: Replacement of sensors, valves, pumps and other faulty components to restore your boiler to optimum operation.
– Preventive maintenance: Implementing preventive measures to prevent problems from recurring, including cleaning ducts, monitoring pressure levels and inspecting ventilation systems.
– System optimization: Adjustment of boiler parameters to improve energy efficiency and extend service life.
Approved for Bulex boilers
Leader Services is authorized to work on Bulex boilers. Our technicians are certified and receive regular training in the latest Bulex technologies and product updates.
This expertise enables us to carry out repairs in compliance with the manufacturer’s standards, guaranteeing the safety and efficiency of your heating system.
List of error codes for Bulex boilers
F.00 / F.01 / F.10 / F.20
Meaning:
– F.00 : Boiler temperature sensor faulty.
– F.01 : Return temperature sensor faulty.
– F.10: Storage tank temperature sensor faulty.
– F.20: Heating system overheating.
Intervention
Sensor diagnosis and replacement :
The heating engineers will check the sensor connections and replace them if necessary.
Checking the electronic control :
Test and reset or replace control module in case of failure.
Preventive Maintenance
Implement measures to prevent overheating, such as cleaning and checking the boiler’s internal components.
F.22 / F.23 / F.24
Meaning:
– F.22: Absence or lack of water in circuit.
– F.23: Overheating due to low water circulation.
– F.24: Overheating due to blocked or faulty pump.
Intervention
Water pressurization :
Check system pressure and refill water circuit if necessary, bleed radiators to remove trapped air.
Pump Inspection and Repair :
Inspect pump for blockages or faults, replace if necessary.
Optimizing Water Circulation :
Check valves and pipes for obstructions.
F.27 / F.28 / F.29
Meaning:
– F.27 : Flame detection problem.
– F.28: Burner ignition failure.
– F.29 : Loss of flame during operation.
Intervention
Checking the gas supply :
Check that the gas supply is stable and that there are no leaks.
Burner cleaning and repair :
Clean burner and check ignition electrode, replace if necessary.
Ensuring adequate ventilation :
Check and clean ventilation ducts to ensure proper combustion.
F.32 / F.33 / F.34
Meaning:
– F.32 : Fan or smoke circuit problem.
– F.33 : Air pressure problem.
– F.34: Incorrect air or gas flow detected.
Intervention
Fan maintenance :
Inspect, repair or replace fan.
Checking smoke ducts :
Check and clean flues to remove any obstructions.
Setting air pressure sensors :
Adjust or replace air pressure sensors to ensure correct operation.
F.35 / F.36 / F.37 / F.38
Meaning:
– F.35: Boiler control problem.
– F.36 : Poor combustion.
– F.37: Water pressure too low.
– F.38: Electrical voltage problem.
Intervention
Control setting :
Check and adjust boiler control parameters for optimum combustion.
Combustion check :
Analysis and correction of combustion problems.
Water pressure stabilization :
Adjust water pressure in the system and check components to avoid pressure loss.
Ensuring a stable power supply:
Check that the power supply is stable and meets the boiler’s requirements.
F.42 / F.43 / F.44
Meaning:
– F.42: Internal control error.
– F.43: Hot water tank overheating.
– F.44: Hot water cylinder temperature sensor problem.
Intervention
Diagnosis of internal components :
Check and replace defective internal control components.
Hot water tank temperature control :
Temperature control to prevent overheating.
Replacing Temperature Sensors :
Replace hot water cylinder temperature sensors if necessary.
F.61 / F.62 / F.63 / F.64 / F.65
Meaning:
– F.61: Gas valve error.
– F.62: Gas valve timing error.
– F.63: EEPROM memory error.
– F.64: Communication error with control unit.
– F.65: Electronic module overheating.
Intervention
Gas valve inspection :
Check and replace gas valve.
Resetting and repairing EEPROM :
Reset or replace EEPROM memory in the event of an error.
Ensuring good communication between components:
Check connections and communication between boiler components.
Electronics module cooling :
Ensure proper ventilation to prevent overheating of the electronic module.
F.67
Meaning:
– F.67: Flame signal error.
Intervention
Flame detection circuit diagnostics :
Check and repair the flame detection circuit to ensure it is working properly.
Cleaning or replacing the flame electrode :